INSTALLATION GUIDEGas Rangetops
Gas Rangetop Specifications 10361/4" (921)OPENING WIDTH30" (762) TO36" (914)TO BOTTOM OFVENTILATION HOOD***Minimum clearance from rough
Gas Rangetop Specifications 11wolfappliance.com/specs481/4" (1226)OPENING WIDTH30" (762) TO36" (914)TO BOTTOM OFVENTILATION HOOD***Mini
Gas Rangetop Installation 12Install the RangetopPrepare the finished opening for the rangetop according todimensions shown in the illustration for you
Gas Rangetop Installation 13wolfappliance.com/specsVerify Rangetop OperationIMPORTANT NOTE: Prior to operating the rangetop, besure to read the entire
Service Information 14TroubleshootingIMPORTANT NOTE: If the gas rangetop does not operateproperly, follow these troubleshooting steps:• Verify that el
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained
WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820816983 REV-A 9/2010
Important NoteTo ensure the safe and efficient use of Wolf equipment,please take note of the following types of highlightedinformation throughout this
Wolf Gas Rangetops 3wolfappliance.com/specsGas Rangetop InstallationIMPORTANT NOTE: This installation must be completedby a qualified installer, servi
WHAT TO DO IF YOU SMELL GAS:•Do not try to light any appliance.•Do not touch any electrical switch.•Do not use any phone in your building.•Immediately
Gas Rangetop Specifications 5wolfappliance.com/specsGas Rangetops36" (914)101/2" (267)TO COOKINGSURFACE48" (1219) RANGETOP48" (121
Gas Rangetop Specifications 6Installation RequirementsIMPORTANT NOTE: Caution must be used in planning theproper installation of the Wolf gas rangetop
Gas Rangetop Specifications 7wolfappliance.com/specsIMPORTANT NOTE: You must follow all National ElectricalCode regulations. In addition, be aware of
Gas Rangetop Specifications 8Agas supply line of3/4"rigid pipe must be provided to therangetop. If local codes permit, a certified, 3' (.9 m
Gas Rangetop Specifications 9wolfappliance.com/specsGas Supply RequirementsGAS MANIFOLD PRESSURE• Natural Gas: Standard orifices are set for 5" (