13
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
WIRING
IMPORTANT NOTE:
The ventilation hood
must be properly grounded. It should be
installed by a qualified electrician in accor-
dance with all applicable national and local
electrical codes.
Power connection at hood:
1)
Run supply conductors to the hood wiring
box marked "120 V AC input".
2)
Remove the cover from the wiring box and
remove one knockout as shown in illus 23.
3)
Secure the conduit to the wiring box
through a conduit connector.
4)
Make electrical connections at the hood.
Connect white-to-white, black-to-black and
green-to-ground.
5)
Replace the wiring box cover and screws.
Make sure wires are not pinched between
the cover and box.
Remove the adhesive tape and slide the lower
flue downward, placing it gently onto the hood
base. Installation is now complete and the
grease filters can be installed.
ISLAND HOODS – DUCTED
Adjust the height of the telescopic flue by
means of the four retaining screws (C) shown
in illus 20. Take into account that the height of
the hood is 3
1
/8" (79) and the bottom of the
hood should be a minimum of 24" (610) and a
maximum of 30" (762) above the countertop.
Take the upper flue (with the round slots) and
slide it on the telescopic flue with the slots
facing upwards. Attach the flue to the bracket
with two screws as shown in illus 21.
Take the lower flue and slide it over the upper
flue, to the top and secure it in that position
using adhesive tape.
Raise the hood to the telescopic flue and
connect the air outlet duct to the hood.
Attach the hood to the telescopic flue by
means of four screws (provided) as shown in
illus 22.
Illus. 22
Illus. 20
Illus. 21 Illus. 23
3.9 x 9.5mm
3.9 x 9.5mm
BOX MARKED
120 V AC INPUT
120 VOLT 60Hz
LINE-IN