Pro Wall Hood Installation 14
IMPORTANT NOTE: R
emove packaging material used to
prevent flap damage during shipping. Damper will not
function properly unless this material is removed prior to
mounting the hood.
5) For internal blowers, mount blower to mounting studs
using nuts supplied with blower. Refer to the illustration
below.
6) Turn back panel assembly upright and reattach using
screws previously removed.
7) Mount damper and two hold-down brackets to the top
of the hood. Damper drops into place and damper
tongues drop into slots on the back panel. Hold-down
brackets clamp on the damper groove overhang.
Secure hold-down brackets using two screws per
bracket. Refer to the illustration below. Seal with
aluminum tape or high temperature duct tape to ensure
a tight seal.
Damper inside hood. Remove damper.
HOLD-DOWN
BRACKET
PACKAGING
MATERIAL
BACK PANEL
Mounting stud location. Mount damper.
HOLD-DOWN
BRACKET
DAMPER
ELECTRICAL BOX
Framing must be able to support the weight of the hood
and internal blower, if applicable.
24" and 27" Deep Wall Hoods
WALL PREPARATION
Minimum 2" (51) x 4" (102) lumber is required to construct
wall framing.
HOOD PREPARATION
Install internal blower prior to mounting hood (if applicable).
1) Hood is shipped with back panel in place. Damper is
attached upside down to inside top surface of back
panel. Damper must be removed and reinstalled in the
proper position. Refer to the illustration below.
2) To remove filters, press upward then rotate bottom
outward. To aide in removal, remove center filter first.
Remove grease cups from bottom edge of hood.
Gloves should be worn when handling filters.
3) Detach back panel and damper assembly from hood
by removing the top and back screws. Do not discard
screws.
4) Turn assembly over and place on a protected work
surface. Separate damper from back panel by
removing the hold-down brackets. Do not discard
brackets and screws. Refer to the illustration below.