Wolf Sealed Burner Rangetops 62
ELECTRICAL AND GAS REQUIREMENTS
Wolf sealed burner rangetops require a 110/120 V AC,
50/60 Hz electrical supply to operate the electronic
ignition system. The 6' (1.8 m) power cord is equipped
with a 3-prong, grounded plug for protection against
shock hazard. The service should have its own 15 amp
circuit breaker.
A gas supply line of
3
/4" rigid pipe must be provided to the
rangetop. If local codes permit, a certified, 3' (.9 m) long,
1
/2"or
3
/4" ID flexible metal appliance connector is recom-
mended to connect the rangetop to the gas supply line.
Wolf sealed burner rangetops are designed to operate on
natural gas at 5" (12.5 mb) WC pressure or LP gas at 10"
(25 mb) WC pressure. The minimum line pressure is 7"
(17.5 mb) WC for natural gas and 11" (27.4 mb) WC for LP
gas. The maximum gas supply pressure to the regulator
should never exceed 14" (34.9 mb) WC, .5 psi (3.5 kPa).
Wolf natural gas rangetops will function up to an altitude
of 10,250' (3124 m) without any adjustment. LP gas range-
tops will function up to 8,600' (2621 m) without adjust-
ment. If the installation exceeds these elevations, contact
your authorized Wolf dealer for a high altitude conversion
kit.
Planning Information
Available in three widths, Wolf sealed burner rangetops
are designed to fit a 30" (762), 36" (914) or 48" (1219)
opening.
The platform must be able to support 200 lbs (91 kg) for a
30" (762) rangetop, 250 lbs (113 kg) for a 36" (914)
rangetop and 300 lbs (136 kg) for a 48" (1219) rangetop.
The platform must include a cut-out at the right rear for
gas supply and electrical connections.
IMPORTANT NOTE: When installing against a combustible
surface, a minimum 5" (127) riser is required for model
SRT366, and a minimum 10" (254) riser is required for 36"
(914) and 48" (1219) sealed burner rangetops with a
charbroiler or griddle. Follow all minimum clearances to
combustible surfaces shown in the installation illustrations
on the following pages.
It is recommended that you use a Wolf pro ventilation
hood or hood liner with the sealed burner rangetop. If the
rangetop is to be installed without ventilation, a 36" (914)
minimum clearance, 44" (1118) for charbroiler, from coun-
tertop to combustible materials above the rangetop is
required. Refer to page 101 for pro ventilation.
A downdraft can be used with models SRT304 and
SRT366. An accessory trim kit is necessary for this instal-
lation. Contact your authorized Wolf dealer for details.
Burner Rating Btu (kW) Btu (kW)
SURFACE BURNERS HIGH SIMMER
Large 15,000 (4.4) 950 (.3)
(1) Small 9,200 (2.7) 325 (.1)
OPTIONAL FEATURES NATURAL LP
Infrared Charbroiler 16,000 (4.7) 16,000 (4.7)
Infrared Griddle 15,000 (4.4) 13,000 (3.8)
Double Griddle 30,000 (8.8) 26,000 (7.6)
French Top 15,000 (4.4) 15,000 (4.4)