Wolf C48SS Spezifikationen Seite 28

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 27
Do not overtighten the thermocouple nut
or the insulator could be crushed, shorting the
thermocouple. Finger tighten the nut plus 1/4 turn with
a wrench only.
If pilot flame is correct and there are no excessive air
drafts in the room, then problem is either the
thermocouple output voltage or the gas safety valve.
Visually check the thermocouple tip (hot end) and tube
lead for:
Loose thermocouple connection (electrical) at
the safety valve.
Corrosion or debris on the threaded connector or
thermocouple tip causing a poor electrical
connection.
Kinks or pinches that might cause a short
between the tube and the wire inside.
If thermocouple is loose, tighten mounting nut as
described above in NOTICE. If thermocouple
connection shows signs of corrosion or debris that
cannot be cleaned; or damage as described, replace
it and check pilot operation as outlined under
PILOT
FLAME HEIGHT.
TKHUPRFRXSOHTHVW
Check the thermocouple output voltage (DC millivolts)
with a VOM as outlined in the steps below.
If thermocouple adaptor (see Tools) is available,
check closed circuit voltage as outlined in the test
procedure.
If thermocouple adaptor is not available, check
open circuit voltage as outlined in the test
procedure.
If a VOM is not available, replace the
thermocouple with a new one as outlined under
STANDARD OVEN PILOT ASSEMBLY AND
THERMOCOUPLE or CONVECTION OVEN
PILOT ASSEMBLY AND THERMOCOUPLE or
and check operation GRIDDLE PILOT
ASSEMBLY AND THERMOCOUPLE.
1. Disconnect thermocouple from gas safety valve.
2. Select the test to perform.
3. CORVHGCLUFXLW.
A. Install thermocouple adaptor at the
threaded connection on gas safety valve.
B. Install thermocouple to the adaptor. Tighten
mounting nut as described above in
NOTICE.
C. Light the pilot. Allow pilot to heat
thermocouple for one to two minutes.
D. Connect one meter lead to the adaptor test
point and the other meter lead to the tube.
Compare reading to the value listed in the
table below.
4. OSHQCLUFXLW
A. Connect one meter lead to the tip of the
threaded end and the other meter lead to the
tube. Compare reading to the values listed
in the table below.
B. Light the pilot and continue to hold red
button down during this test. Allow pilot to
heat thermocouple for one to two minutes.
C. Compare reading to the value listed in the
table below.
T+ER0OCOU3LE09READING6
CORVHGCLUFXLW OSHQCLUFXLW
Range 8 to 25 MV 25 to 35 MV
5. If readings are less than the minimum stated
above, replace the thermocouple as outlined
under
STANDARD OVEN PILOT ASSEMBLY
AND THERMOCOUPLE or CONVECTION
OVEN PILOT ASSEMBLY AND
THERMOCOUPLE or GRIDDLE PILOT
ASSEMBLY AND THERMOCOUPLE.
6. If pilot is still not functioning properly after
replacing thermocouple, then a problem exists in
the gas safety valve. Install a replacement GAS
SAFETY VALVE (STANDARD AND
CONVECTION OVENS) and check for proper
operation.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - SERVICE PROCEDURES AND
ADJUSTMENTS
F45471 (0913) Page 28 of 33